LSL server for Emotiv EPOC X
Original code taken from CyKit
On Windows, install Python 3.11 or newer, then double-click run.bat. The
launcher installs Pipenv (if needed), creates the environment, and installs the
exact versions from Pipfile.lock before starting the LSL streams. The first
run requires an internet connection; later runs reuse the environment.
For manual setup or non-Windows use:
pip install pipenv
python -m pipenv sync --dev
Disable the motion data in Emotiv app settings
Connect dongle, turn on the headset, wait for the light from two indicators
On Windows, run.bat (or the explicit run_epochX.bat) launches the EPOC X
EEG and Cortex LSL streams with the repository's configured developer
credentials. run_flex.bat launches the original EPOC Flex 1.0 path.
run_epochX_legacy.bat is the same EPOC X launcher, but it runs the unmodified
pre-0x740 HID reader. Use it for headsets on firmware older than 0x740 (for
example 0x720): automatic detection does not currently stream from them.
# frist terminal
python -m pipenv run python main.py
Then you can use any lsl client, for example bskl
bsl_stream_viewer
Or use examples/read_data.py to get raw data
# second terminal
python -m pipenv run python examples/read_data.py
If you have a working Cortex app key, this repo can also bridge the Cortex dev
(contact quality) and eq (EEG quality) streams into LSL without changing the
raw HID EEG path.
Set your Cortex credentials:
export EMOTIV_CLIENT_ID=your_client_id
export EMOTIV_CLIENT_SECRET=your_client_secretThen run:
python -m pipenv run python main_cortex.py --print-samplesThis opens two additional LSL outlets when Cortex allows them:
Epoc X Contact QualityEpoc X EEG Quality
You can also enable additional non-motion Cortex streams such as:
pow->Epoc X Band Powermet->Epoc X Performance Metricscom->Epoc X Mental Commandsfac->Epoc X Facial Expressions
Their Cortex sample rates differ:
dev: 2 Hzeq: 2 Hzpow: 8 Hzmet: variable, typically 2 Hz with the right scope/session state, otherwise as low as 0.1 Hzcom: 8 Hzfac: 32 Hz
The bridge now republishes Cortex samples to LSL using the original Cortex sample timestamps converted into the local LSL clock domain, so cross-stream alignment does not rely on arrival timing alone.
Example:
python -m pipenv run python main_cortex.py --streams dev eq pow met com facEPOC X firmware 0x740 uses a different HID encryption protocol from older
firmware. The direct-HID reader now queries the EEG collection's feature report,
derives the firmware-specific AES-256 key, and publishes the raw EEG stream
without a Cortex EEG license. A licensed Cortex application remains an
alternative:
python -m pipenv run python main_cortex.py --streams eegThis creates an Epoc X Cortex EEG LSL outlet. Its columns are the eeg columns
reported by Cortex (COUNTER, INTERPOLATED, the 14 EPOC X sensors, RAW_CQ,
and MARKER_HARDWARE); the MARKERS object column is omitted because an LSL
float32 outlet cannot carry JSON objects. The outlet rate is taken from the
headset's Cortex setting (normally 256 Hz for EPOC X).
The Cortex eeg stream requires a paid license with the eeg scope and an
activated session. The existing default dev eq bridge remains unactivated and
continues to work for quality-only access. EmotivPRO's integrated LSL EEG outlet
is another supported fallback when EmotivPRO is licensed.
No firmware-specific launcher or headset update is needed. On every connection the reader builds both keys it can - the pre-0x740 serial-derived AES-128 key and, when the feature report answers, the 0x740 AES-256 key - and confirms the choice against the decrypted packet counter, which only advances by one per report under the correct key. A headset whose feature report is missing, silent, or misreported therefore still streams.
Interface discovery is also firmware-independent: Emotiv interfaces are matched
on the manufacturer string or the receiver's vendor id (Windows does not
always report the former), and the most likely EEG collection is probed first.
If the dongle is missing or the headset is not streaming yet, the reader waits
and prints Waiting for the EPOC X headset to start streaming. The key and
sample rate are only chosen once real packets arrive.
Automatic detection does not currently stream from 0x720 headsets: the stream
opens but carries no samples. For firmware older than 0x740, use
--firmware legacy. It runs the frozen pre-0x740 reader
(emotiv_lsl/emotiv_epoc_x_legacy.py) with none of the newer discovery,
feature-report, key-verification or rate-measurement steps. That reader
declares 128 Hz unless you pass --sample-rate.
python -m pipenv run python main.py --firmware legacy # unmodified pre-0x740 reader
python -m pipenv run python main.py --firmware legacy --sample-rate 256
python -m pipenv run python main.py --firmware 0740 # force the feature-report keyOn Windows, run_epochX_legacy.bat is the same launcher as run_epochX.bat
with --firmware legacy applied. If a headset is not recognized at all, print
what the operating system actually enumerates:
python -m pipenv run python main.py --list-hidThe direct HID decoder can query the feature report after opening the EEG collection; the steady-state 32-byte EEG dump in issue #17 does not contain the firmware seed by itself. To inspect the exchange, insert the dongle, leave the headset powered off, and run the recorder before powering on the headset. It is fine to leave EMOTIV Launcher running if the Cortex service needs it; the recorder talks to HID directly and does not use Cortex login.
python -m pipenv run python examples/capture_hid_startup.py --seconds 60 >hid_capture.log 2>&1Start the recorder first, then power on the headset and leave it running for a
few seconds. It records both Emotiv HID interfaces and preserves the raw report
length and bytes in data/epocx_startup_hid.csv; serial numbers can be redacted
afterward, but do not alter the report bytes. A USBPcap trace is needed only if
the feature report itself must be inspected; the launcher now performs the
feature query automatically.
Because the Cortex service may initiate the headset session, keep EMOTIV
Launcher running for this capture and allow it to notice/connect the headset
after the recorder has started. The hidapi CSV may contain only steady-state
usage=2 rows; the feature report is a separate control transfer.
The recorder writes diagnostics to stderr, so redirect both streams (>file 2>&1) if you want the console output saved. If both interfaces report
Capturing but the CSV still contains only usage=2 input reports, that is
normal: the feature query is a control transfer and is not emitted as an input
row. A USBPcap/Wireshark capture of the dongle records both directions if
further protocol inspection is needed.
The complete reverse-engineered design, including the firmware gate,
feature-report seed, SHA-256/AES-256 derivation, and downgrade findings, is
preserved in
docs/firmware_0740_hid_path.md.
The capture script is not part of the eventual acquisition workflow. The
decoder collects and caches the feature-report key automatically on each
headset connection while the Cortex service remains running for the quality
streams; no Cortex eeg scope is involved.
Notes:
- The HID recorder does not require a Cortex app key, an EEG license, or an EmotivPRO subscription.
- Do not start a second copy of this repository's launcher or EmotivPRO's EEG stream during capture. EMOTIV Launcher itself may remain running for the Cortex service.
- For a complete USBPcap startup trace, turn the headset off after starting the capture and power it on again. The production decoder can query the feature report even when the headset is already connected.
The separate Cortex bridge uses wss://localhost:6868; quality-only runs
(dev, eq, etc.) use an unactivated open session, while a run that includes
eeg requests an active session and consumes the appropriate EEG license
quota.
The original Flex 1.0 controller uses a different HID protocol from both EPOC X and Flex 2.0. Its direct reader is kept separate while the protocol is being validated:
python -m pipenv run python main_flex.pyThe reader selects the dongle's EEG Signals collection, decrypts its 32-byte
AES-128 reports, and reconstructs the 32 compressed EEG channels at 128 Hz. It
does not require a Cortex EEG license and can run alongside EMOTIV Launcher and
the quality-only Cortex bridge. Flex 1.0 sensor placement is configurable. The
default epoch_flex_electrodes.json is a direct
Emotiv Launcher configuration export; edit that file whenever the plugs are
rearranged. The reader preserves the fixed wire order but publishes the
configured locations as the LSL channel labels, while retaining the wire name
in each channel's wire metadata field. main_all_flex.py also passes the
same mapping object to Cortex when it connects the Flex headset; Flex requires
that object for a discovered-headset connection. A different file can be
supplied with --mapping PATH. The full reverse-engineered path and current
caveats are in
docs/flex_1_hid_path.md.
The direct reader also publishes an Epoc Flex 1.0 Display stream: the same
samples through a one-pole high pass (--display-hz, default 0.5 Hz; 0 turns the
stream off). Flex 1.0 transmits deltas and never an absolute level, so the
recorded stream is a bare integral that wanders by millivolts across a session
and an autoscaled viewer shows that wander rather than the EEG. Point LSL viewers
at the display stream; record and analyse Epoc Flex 1.0. The display copy
has a second high pass on top of the headset's own, which costs slow ERP
components amplitude and adds an undershoot after every large deflection, so
analysis/emotiv/loading.py refuses it by name.
The direct reader also publishes an always-on Epoc Flex 1.0 Packet Diagnostics
LSL stream beside the EEG outlet. It contains the 7-bit packet counter,
expected counter, per-sample gap/reset flags, cumulative missing-report counts
and a FILLED flag. The Flex ADC accumulator is carried across gaps by
default; use --reset-on-gap only to reproduce the legacy midpoint-reset
behavior.
Flex EEG is timestamped from the headset's sample counter, not arrival time. The
dongle otherwise delivers samples 0–70 ms late, by a varying amount. Every lost
sample is published as a filled stand-in (FILLED = 1), so sample number
matches headset time. A lost report's delta is unknown, so a filled sample
holds each channel's level. After a dropout longer than half a second,
RESET_FLAG marks the missing count as an estimate, and publishing pauses for
1 s while the clock resynchronises. See
docs/flex_1_hid_path.md.
To launch Flex EEG and the unlicensed Cortex quality streams together:
python -m pipenv run python main_all_flex.py \
--client-id YOUR_ID --client-secret YOUR_SECRET --remove-dcOn Windows, double-click run_flex.bat. It uses dev and eq by default and
publishes them with the Epoc Flex 1.0 prefix so they do not collide with EPOC
X quality outlets (Epoc Flex 1.0 Contact Quality and Epoc Flex 1.0 EEG Quality). main_all_epochX.py, main_epochX.py, and
run_epochX.bat are explicit EPOC X entry points; the unsuffixed EPOC X
entry points remain as compatibility aliases.
If more than one Emotiv receiver is connected, select the Flex dongle by its HID serial:
python -m pipenv run python main_flex.py --serial UD... --remove-dcThe existing examples/view_contact_quality.py remains the 14-sensor EPOC X
viewer. main_all_flex.py launches the Flex viewer automatically after the
streams start; use --no-viewer for a headless LSL-only run. To view the
current EPOC X contact quality stream as a live head map:
python -m pipenv run python examples/view_contact_quality.pyTo calibrate the complete Flex reference image (all available 10-20 locations, not only the locations active in the current montage):
python -m pipenv run python examples/calibrate_flex_head_image.pyThe points are saved to flex_head_image_coords.json and can be regenerated if
the image or sensor placements change.
The Flex quality viewer downsamples the reference image to a panel width of at most 420 pixels so both quality panels fit on a 1080p display. The calibration values are normalized (0–1), so the overlay locations stay aligned automatically; the calibration JSON does not need to be edited when the viewer scales the image.
If a computer cannot render the PNG correctly, pass --no-background to
main_all_flex.py; the viewer will show the full calibrated coordinate layout
and active quality markers on a plain canvas.
This viewer subscribes to both Epoc X Contact Quality and Epoc X EEG Quality
and renders two live head maps side by side. Each sensor is colored from
black/red through green based on the 0..4 quality scale, while each panel also
shows its overall percentage.
The viewer uses normalized coordinates stored in head_image_coords.json, so the
head image only needs to be calibrated once. To create or update that file:
python -m pipenv run python examples/calibrate_head_image.pyClick the sensor centers in this order:
AF3,F7,F3,FC5,T7,P7,O1,O2,P8,T8,FC6,F4,F8,AF4OVERALL
To launch raw EEG, the Cortex quality streams, and the dual quality viewer from a single command:
python -m pipenv run python main_all.py --client-id YOUR_ID --client-secret YOUR_SECRETTo include the additional optional Cortex streams in the unified launcher:
python -m pipenv run python main_all.py --client-id YOUR_ID --client-secret YOUR_SECRET --streams dev eq pow met com facThis starts:
Epoc XEEG over the raw HID pathEpoc X Packet Diagnostics(counter/gap metadata, timestamped with EEG)Epoc X Contact Qualityfrom CortexdevEpoc X EEG Qualityfrom Cortexeq- the live dual-panel viewer
Change device sampling rate in config.py and emotiv app
Probe hidden quality fields
This repo publishes the 14 EEG channels and an always-on Epoc X Packet Diagnostics stream. Counter discontinuities are also summarized on the console
(the first one immediately, then at most once every ten seconds) so packet loss
is visible without an LSL consumer attached. The diagnostics stream is timestamped alongside the EEG
samples and includes the decrypted packet counter (0..127 at 128 Hz or
0..255 at 256 Hz), expected counter,
per-sample gap/reset flags, cumulative loss/reset counts, and a FILLED flag.
FILLED is always 0 on EPOC X, which does not fill lost samples. A gap flag
marks the first received sample after a counter discontinuity; it does not alter
the EEG values. After a dropout longer than half a second, the missing count
includes whole counter cycles estimated from arrival time, and RESET_FLAG
marks it as an estimate. Use those fields to mark or reject short acquisition
windows in analysis. EPOC X timestamps are arrival times and lost samples are
not filled, so the EPOC X streams tell XDF loaders not to refit timestamps
over sample number; pyxdf honours this automatically. With any other loader,
turn jitter removal off, or a single short dropout can shift timestamps by
tens of milliseconds.
The decrypted packet also contains four non-EEG bytes that are not exposed by default. To inspect whether they carry useful quality information without breaking existing EEG consumers:
python -m pipenv run python main.py --emit-debug --log-decrypted data/decrypted_packets.csvThis keeps the existing EEG outlet and adds a second stream named Epoc X Debug
with four channels:
COUNTERDATA_MODEBYTE16BYTE17
Suggested test protocol:
- Start the EEG and debug outlets.
- Record both in LabRecorder.
- Put the headset on with a good fit, then intentionally worsen one sensor at a time.
- Check whether
BYTE16orBYTE17changes systematically with global fit. - If you have temporary EmotivPro access on one machine, compare the debug stream
against its
Contact-Qualityoutput once to correlate any hidden fields.
If these bytes do not track contact quality, the next step is to treat true contact quality as unavailable on the HID path and implement a separate signal-quality proxy instead of calling it contact quality.
The Flex launcher similarly publishes Epoc Flex 1.0 Packet Diagnostics beside
the 32-channel EEG stream. Flex uses a 7-bit wrapping counter and the same
diagnostic channel names. Unlike EPOC X, it fills lost samples (FILLED = 1)
and timestamps from the counter. Its ADC accumulator is carried across packet
gaps by default; pass --reset-on-gap only when reproducing the legacy
midpoint-reset behavior.
Get raw data:
python main.py & # start lsl server
python examples/read_data.py # get raw data
[4179.35888671875, 4320.5126953125, 4263.84619140625, 4311.53857421875, 4393.58984375, 4347.56396484375, 4371.41015625, 4549.4873046875, 4511.9228515625, 4434.1025390625, 4378.46142578125, 5053.33349609375, 4283.33349609375, 4228.46142578125] 104573.455064594
[4163.33349609375, 4318.0771484375, 4258.7177734375, 4310.384765625, 4396.41015625, 4350.384765625, 4374.615234375, 4550.76904296875, 4508.0771484375, 4429.4873046875, 4374.4873046875, 5058.205078125, 4274.4873046875, 4222.94873046875] 104573.457074205
[4164.615234375, 4316.02587890625, 4255.384765625, 4312.3076171875, 4398.0771484375, 4350.12841796875, 4376.15380859375, 4552.94873046875, 4513.97412109375, 4430.8974609375, 4375.384765625, 5063.7177734375, 4275.384765625, 4225.0] 104573.464060118
[4177.94873046875, 4321.66650390625, 4261.794921875, 4313.46142578125, 4397.1796875, 4347.05126953125, 4373.58984375, 4551.66650390625, 4521.2822265625, 4436.794921875, 4378.7177734375, 5060.76904296875, 4283.7177734375, 4232.8203125] 104573.472085895
Write raw data via mne to .fif:
python main.py & # start lsl server
python examples/read_and_export_mne.py # write raw data to fif file
Ready.
Writing emotiv-lsl/data_2023-09-20 18:36:10.775860_raw.fif
Closing emotiv-lsl/data_2023-09-20 18:36:10.775860_raw.fif