API changes in Evok 3.1 against 3.0

The changes which affect the clients of REST, JSON, Bulk, WebSocket, RPC and the webhook, the configuration and the HW definitions. Breaking changes come first. Every change names its commits (https://github.com/UnipiTechnology/evok/commit/<hash>).

Check on a device before the release

  • Unipi nodes for Node-RED: which Origin header they send to the WebSocket. If they send their own address, Evok refuses them with 403 and the address has to be added to allowed_origins.
  • nginx configuration of the package: it has to pass the original host for the WebSocket (proxy_set_header Host $host, $host:$server_port of evok-web works since b1415ef), otherwise the web interface behind nginx gets no WebSocket. Checked with evok-web 3.18 on a Patron.
  • Outputs written by a coil: if a unit shows the state of an output written by its coil with a delay, the reply to the change has the old state, the next scan corrects it; the written holding registers are kept in the cache, the coils are not.

Breaking changes

Access to the API

  • The default address of the API is 127.0.0.1, before all interfaces. An empty address still listens on all of them. — 5b81429
  • CORS is sent only to the origins of allowed_origins, before * to all. A WebSocket from a browser of another origin gets 403. — 2b7f668
  • The body of a request is limited to 1 MB, a message of a WebSocket client to 64 kB. — ba4212f, 053da5d

Devices and their state

  • Watchdog: — 6ac4eb0, f298e87, fce8d1d
    • its circuit is the name of the unit (1) instead of 1_01, the saved aliases of watchdogs are not assigned,
    • nv_save returns an error and is not in full(),
    • value is 0/1 instead of 0–3, a restart is reported only by was_wd_reset,
    • timeout must be a whole number of ms, at most 65535 (a larger one is cut to it as before); an invalid timeout, value or reset is refused before any change; a changed timeout is an event (#280).
  • AI and AO: modes has only unit and range, without the code of the register and the transformation. — e792e17
  • OwPower: value is always 0/1, before true/false after a write. — 2042b3d
  • DI: ds_mode out of the DirectSwitch mode returns an error, before it was silently ignored. — 96f66c6
  • PWM: the hardware PWM refuses a frequency above 50 kHz. Another division of the frequency: other register values, a more precise frequency and a finer duty. — a05718c
  • Invalid values are refused instead of being processed silently: NaN and infinity, the value '2' of an output, an AO out of its range (before it was clamped), an unknown mode of a DI. — 1a6910c, 891bd4a, 5f15f41
  • NaN and infinite values of AIs and data points are returned as the strings 'NaN', 'Infinity', '-Infinity'. — 5f15f41
  • last_comm of a unit is null before the first communication, before about 1.7e9 s. — 2f323f0
  • 1-Wire sensors of the configuration: no lost: true event right after the start or a restart of the bus, a sensor is read after the bus finds it. A sensor which the search of the bus has not found is reported lost. — 5fa3eca
  • RO, DO, LED: no pulse_duration, timeout (DO) and pending, a pulse is set by the sequencer of the output (/rest/sequencer/<type>_<circuit>, running instead of pending). While it runs, a change of the output except its alias is refused with 409 (RPC -32002), cancel it by the sequencer first. The RPC methods *_set_for_time and output_get stay. — a85fb14, 57492fe
  • Reset and nv_save of a unit: the coil is written once without the retries, no response is not an error, Evok waits for the restart of the unit; before a timeout was retried (the reset was sent twice) and returned 503. The value of nv_save stays 1 for 2 s, a new save is refused meanwhile. — 0ab8d2c, 752616a

Circuits by the HW definitions

  • The relays 17–28 of M403/L403 have the circuits 1_17…1_28, before they replaced the relays 1–12. — 50da3b3
  • The inputs and outputs 17–32 of one feature read the next register. — b71adde, 50da3b3
  • Data points with count > 1 and a 32-bit type take two registers each, so their circuits differ. — 50da3b3

REST and JSON

  • Error statuses: 404 unknown device, 400 invalid data, 401 missing or invalid token, 403 a change with the read-only token, 503 unavailable unit, 500 internal error. — 4b36483, a3f4679, 9f9482c
  • POST /rest/all returns 405, a POST with another part of the URL than /alias returns 404. — 3c8f58e, 34bdcd2
  • The alias all is reserved, an alias has at most 64 characters. — 34bdcd2, 3bae093
  • /rest/* reads also a JSON object (Content-Type: application/json or a body starting with {), its params are validated; before a JSON body was ignored and the POST returned 200 without a change. A JSON body which is not an object is refused with 400 on /rest/* and /json/*, it was a 500. — 23831b4

Bulk

  • The assignments are done by Modbus units, not in the order of the request. An error returns the results of the units done and of the assignments of its unit before it. — a3f4679
  • The global_device_id filter was removed. — 6cd0802
  • device_circuits accepts aliases too, altnames in device_types (e.g. di and input) are merged, before the devices were returned twice. — 854054f

WebSocket

  • Only the commands all, filter, full, set. Before any method of a device could be called. — 8e72731
  • Events are always a list. A slow client gets merged changes, it can miss a short pulse. — 7f827fa, 053da5d

RPC

  • ao_set takes mode instead of the frequency, the ai_set* methods were removed. — af3982c
  • Error codes: invalid params -32602, unavailable unit -32000, a change with the read-only token -32001, internal error -32603 without the text of the exception. — cb94d9f, c8a92a4, 4003436

Other

  • OWFS bus: hostname / port of owserver are an error of the configuration, the bus is not created, use master (see Configuration). One master serves one OWFS bus, a second bus with the same master is not created. — 776b371, dc7b1ee

  • print_log of modbus_slave was replaced by GET /log. — 54fe858

New features

  • Communication of the devices: the state of each device of a Modbus unit and of a 1-Wire sensor has comm (ok, timeout, error; a 1-Wire sensor only ok, timeout) and last_comm (seconds since the last successful communication); a lost and a recovered unit sends the states of all its devices, value is the last known one. The entities of Home Assistant are unavailable without the communication. — 969798e
  • Security: an optional token for all APIs (Bearer, Basic, ?token= for the WebSocket) and allowed_origins. — 763016c, 2b7f668
  • Client behind a proxy: trusted_downstream of apis, the addresses of the reverse proxies (e.g. nginx of evok-web) whose X-Forwarded-For / X-Real-IP give the address of the client in the log of Evok.
  • Read-only token: an optional read_token (requires token). It allows reading by REST and JSON, the queries of bulk, all, full, filter and the events of the WebSocket, the reading methods of RPC and /log. A change of a device returns 403 ReadOnlyAccess, by RPC -32001; a bulk with a change is refused as a whole. — 4003436
  • GET /log?lines=N returns the end of the log. — 54fe858
  • POST /modbus_slave/{circuit} with scan_enabled and the alias. full() returns scan_enabled and scan_error. — 2319b2b, 96ba320, d1add77
  • Data points can be written by writable, full() returns it. — eb4eda5, e792e17
  • Sequencer of each output (RO, DO, LED), the device sequencer with the circuit <type>_<circuit> (/rest/sequencer/do_1_01): a pulse (value, pulse_duration), a sequence of the changes of the output (steps, final) or cancel; its state has running and the progress, an event at the start, steps and end. A step failed by an error of the communication (e.g. a noise on the bus) is written again after 1 s up to 30 s, the sequence stays running, the output does not stay in the state of a pulse; a step refused by the unit ends the sequence after its final state (if it has one) is written. The RPC method relay_set_for_time. — e16a3bf, 7789635, a85fb14, #280
  • An invalid alias in a change (a circuit, reserved, invalid or already used) is refused before the first write, the output was switched and then the request failed. The aliases of a bulk are checked in the order of the changes, an alias released by an earlier change can be taken. — #280
  • The reply to POST, bulk and the WebSocket set has the state after the writes and the event comes at once. — a3f4679
  • New events: — 60e2287, 08d9f56, 62b37ef, 891bd4a
    • a changed alias of a device on a Modbus unit,
    • a lost and a restored communication with a unit,
    • a change of counter_mode, the mode and the debounce of a DI,
    • a changed PWM frequency, of all DOs which share it,
    • a change of the 1-Wire power (owpower, value 1 is the bus without power).
  • A successful bulk reply has "success": true. — ba4212f
  • scan_error of modbus_slave and the errors of an unavailable unit name the root cause, e.g. a missing serial port. — d990fe1
  • Deleting the alias of a device which is not connected by POST /rest/run/alias with delete. — b7cebd6
  • GET /rest/serial_bus/{bus} and /rest/tcp_bus/{bus} return the configuration of a Modbus bus and its devices, before a 500 error. The buses are read-only and not in /rest/all. — b40a57c
  • MQTT API: the states of the devices are published to a broker (retained), the commands are received by <prefix>/<device>/<circuit>/set, the status online / offline with the last will. — c8ff385
  • Home Assistant: ha_discovery of the MQTT API announces the devices by the MQTT discovery. — 0538f51
  • Configuration: apis.rpc.enabled, min_interval of the webhook, timeout, connect_timeout and retries of the buses. — f7ebda1, 0044241, 16463d5, a6ede44
  • Outputs without coils: RO, DO and LED without val_coil write their bit of val_reg (a holding register), e.g. a unit which has no coils. A DO without the PWM registers is a simple output, modes is optional. — 05ad76c
  • Serial ports of a unit: serial_ports of a Modbus device lists the serial ports it serves, e.g. the local unit 1 of a Patron M527 with /dev/ttyNS0. Their MODBUSRTU buses are held during the reset and the NV save of the unit and 0.5 s after it, a request on the port corrupts the write of its flash (a bug of the firmware). An option of a device of a MODBUSTCP bus; the reset and the NV save by another Modbus master of the unit are not covered. evok-autogen.py sets it for the boards BRAIN, E4AI4AO4DI5RO, E4AI4AO6DI5RO and E8AI4DI5RO, ttyNS0, ttyNS1... by their order.
  • evok-autogen.py: --config-dir (-d) is the directory of autogen.yaml and hw_definitions (/etc/evok by default), --product-id (-p) the product id instead of UNIPI_PRODUCT_ID, e.g. to generate autogen.yaml of Evok in a virtual environment. An invalid id or a missing directory is an error of the arguments.

Deprecated

  • time of a 1-Wire sensor, the time of the event loop of the read; last_comm replaces it. — 969798e
  • counter_mode and counter_modes of a DI. Disabled only reports the counter as 0, the mode is not saved. — a5d8065
  • The param timeout of the RPC method output_set_for_time is an alias of pulse_duration. — e16a3bf
  • nv_sav_coil of the WD feature is not used, the settings are saved by the NV_SAVE feature. — f298e87
  • frequency of a register block is a deprecated alias of scan_divider, a warning is logged, both in one block are an error. The value is a divider of the scans, not a frequency. — d95f57a
  • The REGISTER feature of the HW definitions, a warning is logged. A DATA_POINT with datatype: uint16 replaces it, its devices are data_point instead of register, without _inp in the circuit of an input register. — fec507a, 97ca903

Configuration and HW definitions

An invalid value is an error: the unit or the feature is not created and the error is logged.

  • Tokens: token and read_token must be non-empty strings, read_token requires token and must differ from it; allowed_origins is a list of http/https origins. Otherwise Evok does not start. — 763016c, 2b7f668, 4003436
  • Unit: scan_frequency > 0, scan_enabled only true/false, slave-id 1–247 on RTU and 0–255 on TCP. — d1add77, 96ba320
  • Register blocks: at most 125 registers, addresses up to 65535, no overlaps. — 2f323f0, 9f9482c
  • Modbus devices: the name must be unique over all buses. The second device with the same name is not created, before it replaced the first one in the API and its IOs were missing. — d8acc38
  • Unit which does not respond: it is probed by one request with probe_timeout of the bus (0.1 s on RTU) without the retries, before every attempt locked the bus for (retries + 1) * timeout (1 s by default) and the other units of the bus waited. — 30cb46f
  • Priority of the changes on a bus: the writes of a change and the read after them go before the scans of the bus, the change does not wait for the running scan of its unit, only for the request being sent. The scan of the unit waits until the change ends, it does not read the unit between its writes; the other units use the bus meanwhile. After each change a waiting scan of the unit and of another unit go first, a stream of changes does not stop the scans. A change waited for the scans of all units of a busy bus, e.g. about 30 requests with 6 units, now about 5. — #267
  • Read after a change: only the register blocks read by every scan (scan_divider: 1), the blocks of the states of the changed devices and of the written registers, the other blocks are read by the periodic scan. A change read all blocks, e.g. a LED of an xS51 a write and 6 reads, now a write and 2 reads (the fast block, the block of the LED). A reset of the unit or NV save reads all blocks, a change without such a block reads the first block of the unit, it finds whether the unit responds. — #267
  • Written registers after a change: a written holding register keeps its value in the cache for 1 s, the reads during it (after the change, by the periodic scan, also of a block read by every scan) do not overwrite it and a next write renews it; then the periodic scan reads its block, a value refused by the unit is seen then. A unit may set a written register with a delay, e.g. xS52 the mode of its AI in 0.3–0.8 s: the read returned the old mode and the switch seemed to fail, it was seen by the next scan of the slow block after several seconds. A unit without the periodic scan (scan_enabled: false) shows the value read after the change. — #278, #279
  • Modbus addresses: a serial port can be used by one MODBUSRTU bus only, the slave-id must be unique on an RTU bus and on a TCP server (hostname, port) over all MODBUSTCP buses. The second bus or device is not created, before both read and wrote the same unit. — dc7b1ee
  • Circuits: a duplicate circuit is an error of the feature, start_index applies also to RO, DO and LED. — 50da3b3
  • Modes: the value of a mode must be a unique integer, the datatype of an AI transformation must be known. — e005aa4, a053e80
  • Data points: a writable data point in an input register is an error. — e792e17
  • Watchdog: one per unit, count is not used. — 6ac4eb0
  • 1-Wire: the type DS2404 is not supported, it has no PIO and was always lost. The address of a sensor is found also without the CRC, the dots or in lower case. scan_interval: 0 searches the bus only after the connection and on request, before once per hour; a changed scan_interval applies at once. — 4ecdf2f
  • OWFS buses: the name of a 1-Wire sensor must be unique over all OWFS buses, a duplicate configured sensor is not created, a found one is skipped; before the second sensor replaced the first one in the API. — fa35a94
  • OWFS bus by the kernel: the sensors are read by the 1-Wire subsystem of the kernel (/sys/bus/w1), owserver and asyncowfs are not used. The option master (w1_bus_master1, the first one by default) instead of hostname / port, the status of the bus has master. The address and the circuit of a found sensor stay the same. The value of a DS2406 is the state of its channel flip-flops. With the udev rule etc/udev/rules.d/60-evok-w1.rules do_scan forces a search and the thermometers are converted at once. — 776b371, 2bb5167

Runtime and installation

  • Python 3.12, tmodbus instead of pymodbus. — 862d760, 733871c
  • tornado 6.5.10 instead of 6.3.3. — 1210fb1
  • Each module logs by its own logger, e.g. evok.modbus.client or evok.w1.bus, the level of one part can be set separately; the level and the log file stay on the logger evok. — 48ab81e
  • 1-Wire by the kernel: the driver of the master (e.g. ds2482) and the modules of the sensors instead of the package owserver; no dependency asyncowfs and anyio. The package should install the udev rule etc/udev/rules.d/60-evok-w1.rules (group evok). — 776b371, 9790404, 2bb5167
  • The options --config-dir and --alias-file (variables EVOK_CONFIG_DIR, EVOK_ALIAS_FILE). Without config.yaml Evok exits with an error. — af85489
  • The OpenAPI document Evok_API_OAS.yaml is generated from the schemas of the sources (python -m evok.openapi) and attached to each GitHub release, it is not in the repository. — 9c2d987, 8ccf4d5

Compiled from the messages of the commits between Evok 3.0.6 and 3.1 and from the changes of the API documentation; after 3.0.6 the branch main had only the changes of the docs and the fix of the WebSocket blocking the requests (#191). The code of Evok 3.0.6 was not compared line by line, details which the commit messages do not describe may be missing.